Feature Overview
This device is an inline PCB thickness detection equipment. When the PCB is conveyed into the machine via rollers, the board is lifted to separate it from the transport surface (preventing surface scratches), and the mechanism performs a centering action. The centered board then passes through the thickness sensing area for upper and lower data collection. The collected data is analyzed by a computer to determine the current thickness of the board. It can be paired with good/bad product sorting machines and printers for use.
Product Specifications
Dimensions: Length × Width × Height | 1440*1190*1812mm |
PCB thickness | Min.:0.2mm Max:3.0mm |
Board Size | Min:300mm* 300mm Max:725mm *625mm |
Testing method | Non-contact (laser) |
Static Repeatability Accuracy | ± 0.003-0.005mm Measurement accuracy is subject to environmental influences.) |
Dynamic Measuring Precision | ± 0.006-0.008mm (Measurement accuracy is subject to environmental influences.) |
Noise | Noise level (operational): ≤ 75 dB |
Control Panel | Touchscreen operation |
Protection Device | Safety Light Curtain、Emergency Stop Device |
Failure Rate | ≤ 1/400h( Failure Time / Operating Time) |
Control Console Height | 1000±100mm |
Capacity
Throughput: 8/min (12 pts/board)
Communal Requirement
Electrical requirements | |
Power Supply | Single-phase 220VAC |
Pressure of compressed air | ≧ 6.5bar |
Compressed Air Pressure | 1.5KW |
Compressed air consumption | 2 m³/h (connection: φ10mm pneumatic fitting) |
Recommended space around machine | 800mm |
Machine Weight | 480KG |
Installation Environment Requirements (Temperature/Humidity/ Cleanliness) | A. Cleanroom Grade 100,000 or higher B. Temperature requirement: 22±2℃ . C. Relative Humidity: 50% ±5% RH |